Inventory Index  >  Refrigeration  >  Ammonia Refrigeration  >  Recirculators

Used Reco Ammonia Recirculator Package. Nominal capacity: 1,290 gallons. Inside straight-wall dimensions: 54 inches diameter x 9 feet 5 inches L. Refrigerant: R-717 [Ammonia]. MAWP: 150 psi @ 300F. Head thickness: .375 inches Shell thickness: .375 inches Radius: 2:1 elliptical ends. Viking pump: Model: QR124. Toshiba pump motor: 5 horse power, 875 rpm, 16.4/8.20 amps, 230/460 V, 60 Hz, 3 phase. Inlets: [1] 10 inches diameter port, [1] 1 inches diameter port. Outlets: [1] 8 inches diameter port, [2] 6 inches diameter port, [1] 1-1/2 inches diameter port, [1] 1 inches diameter port. Overall dimensions: 12 feet 3 inches length x 6 feet 2 inches height x 10 feet height.{h9}.

Click here for more information (pdf - 602.1 KB)

Stock No: re_KWBF197.1  |   Mfg: Reco  |   Model:   |   S/N: re_W-943-6-1

Click here for more information (pdf - 118.0 KB)

Stock No: re_BDPC268.2a  |   Mfg: Reco  |   Model:   |   S/N: re_M876240A

Used 1999 RVS / Evapco Recirculating System. Refrigerant: R-22(Freon). Capacity: 222 gallons. Tank dimensions: 24 inch Diameter x 10 feet 5 inches H. MAWP 250 psi at -20F to 300F. MDMT: -50F at 100 psi. Horizontal oil pot: 12 gallon capacity. Oil pot dimensions: 10-3/4 inches x 3 feet. MAWP 300 PSI, -20F to 300F, MDMT: -50F at 120 psi. 2001 Cornell pump: model: 2CBS-CC, size: 4-3-8.00. Capacity: 20 gpm at 35 PSID, minimum temperature: -60F, 2 hp/ 3 hp, 190-380/230-460V, 3.5-7/4.1-8.2 amps, 1450 /1750 rpm, 50/60 Hz, 3 phase. 1999 Cornell pump: model: CBS-3-4, size: 4-3-8.00. Capacity: 20 gpm at 35 PSID, minimum temperature: -60F, 2 hp/ 3 hp, 190-380/230-460V, 3.5-7/4.1-8.2 amps, 1450 /1750 rpm, 50/60 Hz, 3 phase. 1999 Cornell pump: model: CBS-3-4, size: 4-3-8.00. Overall dimensions: 6 feet 3 inches L x 4 feet 4 inches W x 16 feet 4 inches H.

Click here for more information (pdf - 312.2 KB)
Click here for drawings (pdf - 512.0 KB)

Stock No: re_DFDT18.30  |   Mfg: RVS / Evapco  |   Model:   |   S/N: re_990743

1999 RVS Ammonia Liquid Transfer Unit. Vessel certified by Refrigeration Valves and Systems Corp. Bryan TX USA. Serial: 981086. Natl. Bd.: 11869. MAWP: 250 PSI at 250 F. MDMT: -20F at 250 PSI. Year: 1999. Features RVS Control Box, vessel and misc valves. Vessel measures 18 in. dia. x 48 in. H. Overall dimensions: 4 ft. 6 in. L x 5 ft. 6 in. W x 8 ft. 2 in. H.

Click here for more information (pdf - 346.6 KB)

Stock No: re_IME5051.1a  |   Mfg: RVS  |   Model:   |   S/N: re_981086

1994 RVS Vertical Ammonia Recirculator. Approximate capacity: 1,500 gallons. Inside straight-wall dimensions: 60 in. dia. x 12 ft. H. Refrigerant: R-717 (Ammonia). MAWP: 250 psi at 300F. MDMT: - 40F at 100 psi. Radius: 2:1 elliptical ends. Inlets: (1) 10 in. dia. port (suction in), (1) 2 in. dia. port (makeup liquid), (1) 3 in. dia. port (liquid feed). Outlets: (1) 8 in. dia. port (suction out), (2) 3/4 in. dia. ports (vents), (1) 6 in. dia. port (pump suction). Control panel with (9) push buttons and (6) switches. Panel dimensions: 2 ft. L x 11 in. W x 1 ft. 5 in. H. Hoffman control panel. Cat No: A-1212CH. Panel dimensions: 1 ft. 1 in. L x 6-1/2 in. W x 1 ft. 4 in. H. Overall dimensions: 6 ft. 8 in. L x 6 ft. 6 ft. W x 17 ft. H.

Click here for drawing (pdf - 1,831.1 KB)
Click here for more information (pdf - 786.7 KB)

Stock No: re_RPCN075A  |   Mfg: RVS  |   Model:   |   S/N: re_94279

RVS Horizontal Ammonia Recirculator Tank. Refrigerant: R-717 (Ammonia). Straight wall dimensions: 78 in. dia. x 9 ft. 6 in. L. Approx 2350 gallons. MAWP 150 psi at 300F. MDMT: -20F at 150 psi. Approximate overall dimensions: 10 ft. 10 in. L x 8 ft. 4 in. W x 16 ft. 8 in. H.(HB1).

Click here for drawing (pdf - 730.3 KB)
Click here for more information (pdf - 134.2 KB)

Stock No: re_DFDT07  |   Mfg: RVS  |   Model:   |   S/N: re_87409

Used Howe Corporation Recirculator. Model: PVL264. Approximate capacity: 900 gallons. Inside straight-wall dimensions: 48 inches diameter x 9 feet 6 inches L. Refrigerant: last used with R-22. MAWP: 250 psi at 650F. [2] Cornell pumps, model: 2CB5-4, with Marathon electric pump motors, 5 horse power, 1735 rpm, 230/460 V, 13.2/6.6 amps, 60Hz, 3 Phase. Impeller diameter: 8- inches Inlets/Outlets: [2] 3 inches diameter ports, [2] 1 inches diameter port, [1] 6 inches diameter port, [1] inches diameter port, [2] 4 inches diameter ports, [2] 2 inches diameter ports, [1] inches diameter port, [1] inches diameter port, [1] 1 inches MNPT port. Overall dimensions: 12 feet length x 5 feet 4 inches width x 11 feet H.[HB2][ACN371-85].

Click here for more information (pdf - 703.6 KB)

Stock No: re_MDFP125  |   Mfg: Howe Corporation  |   Model: PVL264  |   S/N: re_5480

Stock No: re_BDPC487.12a  |   Mfg: Frick  |   Model:   |   S/N: re_43276

Used E. L. Nickell High Stage Vertical Ammonia Recirculator Package. Model: C-7761-H. Approximate capacity: 2,250 gallons. National Board: 84753. MAWP: 150 psi. at 650˚F. and -20˚F. [2] Cornell pumps, Model: 2CB, Marathon electric motors, 5 horse power, 1735 rpm, 230/460V, 60 Hz, 13.2/6.6 amp. Oil pot. Recirculator dimensions: 5 feet 5 inches diameter x 12 feet L.

Click here for more information (pdf - 703.4 KB)

Stock No: re_BNCA167.5  |   Mfg: E. L. Nickell  |   Model: C-7761-H  |   S/N: re_37556

Used Frick Recirculating Tank. Approximate capacity: 700 gallons. Refrigerant: R-717 [Ammonia]. MAWP: 150 psi @ -20F to 200F. [2] Cornell pumps with Marathon electric motors: 2 hp, 1740 rpm, 230/460V, 60 Hz, 3 phase. Frick PRR control panel. Hansen Technologies Variable-Level LB3 control panel. Henry Valve Co. LI-49, sight glass. [2] Cyrus Shank safety relief valves, type: 803 TD. Overall Dimensions: 12 feet 8 inches L x 7 feet W x 10 feet 5 inches H.

Click here for more information (pdf - 597.3 KB)

Stock No: re_BDBS03  |   Mfg: Frick  |   Model:   |   S/N: re_261826

Used Reco Vertical Ammonia Recirculator Package. Refrigerant: R-717 [Ammonia]. Approximate capacity: 1,000 gallons. MAWP: 150 psi at 300F. MDMT: -20F at 150 PSI. Inside straight wall: 4 feet diameter x 10 feet height. Radius: 2:1 elliptical ends. Inlets: [1] 1 inches diameter port, [1] 2 inches diameter port, [1] 6 inches diameter port. Outlets: [3] 6 inches diameter port, [1] 3/4 inches diameter port, [1] 2 inches diameter port. Reco oil pot, MAWP: 300 psi at 300F, MDMT: -20F at 300 psi. Cornell ammonia pump, Model: 3CB-F16. Flow rate for new pump is 470 gallons per minute with required horsepower and pressure. Impeller diameter: 15.22 inches Inlet: 6 inches suction. Outlet: 3 inches discharge. Overall dimensions: 5 feet 5in. length x 5 feet 6 inches width x 15 feet 3 inches height.

Click here for more information (pdf - 438.8 KB)

Stock No: re_KWBF917  |   Mfg: Reco  |   Model:   |   S/N: re_19025-260A

Used Reco Vertical Ammonia Recirculator Tank. Refrigerant: R-717 [Ammonia]. Approximate capacity: 1,000 gallons. Inside straight wall dimensions: 48 inches diameter x 9 feet 9 inches height. MAWP: 150 psi at 300F. MDMT: -40F at 100 psi. Radius: 2:1 elliptical ends. Reco oil pot, MAWP: 300 psi at 300F. MDMT: -20F at 300 psi. Radius: 2:1 elliptical ends. Inlets: [1] 8 inches diameter port, [1] I inches diameter port. Outlets: [2] 4 inches diameter port, [1] 8 inches diameter port, [1] 3/4 inches diameter port, [1] 1-1/2 inches diameter port. Overall dimensions: 7 feet 5 inches length x 5 feet width x 15 feet 4 inches height.

Click here for more information (pdf - 293.2 KB)

Stock No: re_KWBF918  |   Mfg: Reco  |   Model:   |   S/N: re_19025-230-A

ISF Vertical Desuperheater / HT Ammonia Recirculator. Sidewall dimensions: 42 in. dia. x 10 ft. High. Certified by Industrial Service & Fabricators, Inc. Burleson Texas. MAWP: 250 PSIG at 200F. MDMT: -20F at 250 PSI. Serial 02-4538. Year: 2002. Natl Bd.: 4225. *Drawings are available.

Click here for drawings (pdf - 192.7 KB)

Stock No: re_BDPC281.42a  |   Mfg: Industrial Service & Fabricators, Inc.  |   Model:   |   S/N: re_02-4538

Horizontal RECO Ammonia Recirculator Package 48 in. diameter x 144 in. long. Approx 1100 gallons. Overall dimensions: 12 ft. 8 in. W x 6 ft. 11 in. L x 9 ft. 10 in. H.

Click here for more information (pdf - 300.9 KB)

Stock No: re_AANF046B  |   Mfg: Reco  |   Model:   |   S/N: re_

Click here for more information (pdf - 113.9 KB)

Stock No: re_AANF131B  |   Mfg: Not Specified  |   Model:   |   S/N: re_

Stock No: re_BATX503  |   Mfg: FES  |   Model:   |   S/N: re_

Click here for more information (pdf - 98.9 KB)

Stock No: re_BDPC486.22a  |   Mfg: Frick  |   Model:   |   S/N: re_

Stock No: re_BDPC497.15  |   Mfg: Not Specified  |   Model:   |   S/N: re_

Stock No: re_BDPC498.17a  |   Mfg: Frick  |   Model:   |   S/N: re_

Frick Horizontal Ammonia Recirculator Package. Vessel built by the Frick Company Waynesboro, PA USA. Natl Bd.: 36443. ASME UW-12-C. Year: 1971. CRN: N/A. MAWP: 150 PSIG / F.V. at -20 to +200F. MDMT: -50F at 60 PSIG. UCS 66. Estimated capacity: 275 gallons. Walter H. Eagan Co. Inc. Ammonia Pumps: model E-HL-924V, serial ST229268, Philadelphia PA USA. Reliance AC motor: 1HP, 115/230V, 14.2 / 7.1 amps, 60 Hz, single-phase. Overall dimensions 12 ft. 5 in. L x 4 ft. 6 in. W x 10 ft. 1 in. H.

Click here for more information (pdf - 445.7 KB)

Stock No: re_IME5056.3  |   Mfg: Frick  |   Model:   |   S/N: re_

Used Niagara "No-Frost"® Evaporator with Ammonia recirculator Package. 10' x 24' x 10'. w/ ammonia tank and pumps.

Click here for more information (pdf - 454.0 KB)

Stock No: re_RGMP154.5  |   Mfg: Niagara  |   Model: No Frost  |   S/N: re_

(2) Horizontal Ammonia Recirculators - 12 ft. L x 4 ft. dia. with (4) pumps and operators platform.

Click here for more information (pdf - 84.0 KB)

Stock No: re_RPCA1302.25  |   Mfg: Not Specified  |   Model:   |   S/N: re_

Horizontal Ammonia Recirculator Package. Overall dimensions: 11 ft. 6 in. L x 6 ft. 9 in. W x 12 ft. H.

Click here for more information (pdf - 211.9 KB)

Stock No: re_RPCA1321C  |   Mfg: Not Specified  |   Model:   |   S/N: re_

Horizontal Ammonia Recirculator Package - 20 ft. L x 8 ft. dia. Skid mounted with 3 pumps. Approx 7500 gallons.

Click here for more information (pdf - 300.5 KB)

Stock No: re_RPCA1363G.47a  |   Mfg: Not Specified  |   Model:   |   S/N: re_


© 2012 refrigeration-equipment.biz - All Rights Reserved.